Water Treatment

Boiler / Cooling Tower Chemicals

Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.

View All Water Treatment Chemicals
Corrosion / Scale Control for Boiler +
  • Corrosion Scale Treatment Boiler - RXSOL-42-4029-025
  • One Shot Universal LiquiTreat - RXSOL-50-5001-020
  • MULTIPLUS BWT - RXSOL-50-5011-020
  • Sludge Conditioner - RXSOL-50-5008-020
  • Oxygen Scavenger Plus - RXSOL-50-5022-025
  • Condensol Corrosion Control - RXSOL-50-5005-025
Cooling Tower / Chiller Unit Maintenance +
  • RXSOL 2000 Corrosion Scale Inhibitor - RXSOL-40-2000-025
  • Corrosion Inhibitor MULTI Metal Protection - RXSOL-40-4011-025
  • Biocide MICRO Cooling Water - RXSOL-40-4009-025
  • Corrosion Inhibitor Antifoulant - RXSOL-40-4027-025
  • Antiscalant Antifoulant - RXSOL-33-3302-025
  • Cooling Water Test Kit - RXSOL-62-5508-001
Marine Chemicals

Marine Deck Engine Chemicals

One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc

View All Marine Chemicals
Deck Engine Maintenance +
  • Heavy Duty Degreaser - RXSOL-10-1005-025
  • TPOL Heavy Duty - RXSOL-20-T300-025
  • All Purpose Cleaner - RXSOL-12-1501-020
  • Fuel Emulsion Breaker - RXSOL-70-7003-020
  • Evaporator Treatment - RXSOL-51-6001-020
  • Electrosol Electrical Cleaner - RXSOL-16-1009-025
  • Carbon Remover - RXSOL-16-1003-025
  • Rust Stain Remover RSR - RXSOL-13-1096-025
  • Enviro Degreaser Cleaner - RXSOL-20-3001-025
  • Hand Cleaner Paste - RXSOL-16-1001-001
Ship Hold Tank Cleaning+
  • Slip Barrier Coat HOLD - RXSOL-22-2210-210
  • RXTuff High Foam - RXSOL-22-3019-210
  • Metal Clean Bright HD - RXSOL-20-1011-020
  • Coal Remover RX Hold - RXSOL-22-2215-210
  • RXSOL PCS Pet Coke Cleaner Hold - RXSOL-22-2208-025
  • Acqua Tuff High Foam - RXSOL-22-3033-210
  • Alkaline Safety Liquid - RXSOL-20-2005-026
Raw Materials

Raw Material Chemicals

Ready stock of fast-running chemical raw materials in 6 key locations of India

View All Chemicals
Inorganic / Organic Powders+
  • Caustic Soda
  • Caustic Potash
  • Sodium Nitrite
  • Sodium Bisulphite
  • Sodium Bicarbonate
Detergent Manufacturing Products+
  • Acid Slurry
  • SLES
  • SLS
  • Nonyl Phenol Ethoxylates
Other Products+
  • Hydrochloric Acid
  • Sodium Hypochlorite
  • Phosphoric Acid
  • Mono Ethylene Glycol

Potassium Chromate

Product Code: RXSOL-60-6112-020


Product Short Description: Potassium Chromate Pure indicator for determination of Chloride by titration method.
Product Description:
Potassium Chromate is used as an indicator in the determination of Chloride by titration with standard Silver Nitrate solution. This method is called the Mohr method of determining Chloride and is based on the formation of a red precipitate of Silver Chromate at the endpoint after all the Chloride has been precipitated as white Silver Chloride. A 5% solution of Potassium Chromate that has been Chloride neutralized is commonly used. Approximately 1 mL of this indicator should be used per 100 mL of sample volume.
Product Application:

The accuracy of the Mohr method decreases as the Silver Nitrate concentration decreases due to the amount of excess Silver Nitrate that must be added to produce enough Silver Chromate to be seen visually. The Mohr method must also be performed in the pH range of 6.5 to 9. If the pH is too high, brownish Silver Hydroxide forms and masks the endpoint. If the pH is too low, the Chromate is converted to Dichromate and the endpoint comes too late or can not be perceived at all. In the presence of Ammonium ions, the pH must be kept below 7.2 to prevent partial conversion of the precipitate to soluble Ammine complexes.

Product Dose:

For comparison purposes, all Mohr tirations should be carried out at about the same temperature, since the solubilities of Silver Chloride and Silver Chromate depend on temperature. Good stirring during the addition of the Silver Nitrate is also required; otherwise, Silver Chromate that forms locally before the endpoint can become occluded in the Silver Chloride precipitate instead of redissolving. Poor agitation could lead to an endpoint that is neither sharp nor reproducible. The reactions for the Mohr titration are:

 
Ag+ + Cl- → AgCl (white precipitate)
 
2 Ag+ (excess) + CrO42- → Ag2CrO4 (red precipitate at endpoint)
Product Note:
Remarks:
Product Tag Identification:
Product Useful Area:

Keyword

Packaging Size

Supply Location

Potassium Chromate manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Potassium Chromate at a competitive price from us. We have ready stock of Potassium Chromate in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.