Water Treatment

Boiler / Cooling Tower Chemicals

Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.

View All Water Treatment Chemicals
Corrosion / Scale Control for Boiler +
  • Corrosion Scale Treatment Boiler - RXSOL-42-4029-025
  • One Shot Universal LiquiTreat - RXSOL-50-5001-020
  • MULTIPLUS BWT - RXSOL-50-5011-020
  • Sludge Conditioner - RXSOL-50-5008-020
  • Oxygen Scavenger Plus - RXSOL-50-5022-025
  • Condensol Corrosion Control - RXSOL-50-5005-025
Cooling Tower / Chiller Unit Maintenance +
  • RXSOL 2000 Corrosion Scale Inhibitor - RXSOL-40-2000-025
  • Corrosion Inhibitor MULTI Metal Protection - RXSOL-40-4011-025
  • Biocide MICRO Cooling Water - RXSOL-40-4009-025
  • Corrosion Inhibitor Antifoulant - RXSOL-40-4027-025
  • Antiscalant Antifoulant - RXSOL-33-3302-025
  • Cooling Water Test Kit - RXSOL-62-5508-001
Marine Chemicals

Marine Deck Engine Chemicals

One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc

View All Marine Chemicals
Deck Engine Maintenance +
  • Heavy Duty Degreaser - RXSOL-10-1005-025
  • TPOL Heavy Duty - RXSOL-20-T300-025
  • All Purpose Cleaner - RXSOL-12-1501-020
  • Fuel Emulsion Breaker - RXSOL-70-7003-020
  • Evaporator Treatment - RXSOL-51-6001-020
  • Electrosol Electrical Cleaner - RXSOL-16-1009-025
  • Carbon Remover - RXSOL-16-1003-025
  • Rust Stain Remover RSR - RXSOL-13-1096-025
  • Enviro Degreaser Cleaner - RXSOL-20-3001-025
  • Hand Cleaner Paste - RXSOL-16-1001-001
Ship Hold Tank Cleaning+
  • Slip Barrier Coat HOLD - RXSOL-22-2210-210
  • RXTuff High Foam - RXSOL-22-3019-210
  • Metal Clean Bright HD - RXSOL-20-1011-020
  • Coal Remover RX Hold - RXSOL-22-2215-210
  • RXSOL PCS Pet Coke Cleaner Hold - RXSOL-22-2208-025
  • Acqua Tuff High Foam - RXSOL-22-3033-210
  • Alkaline Safety Liquid - RXSOL-20-2005-026
Raw Materials

Raw Material Chemicals

Ready stock of fast-running chemical raw materials in 6 key locations of India

View All Chemicals
Inorganic / Organic Powders+
  • Caustic Soda
  • Caustic Potash
  • Sodium Nitrite
  • Sodium Bisulphite
  • Sodium Bicarbonate
Detergent Manufacturing Products+
  • Acid Slurry
  • SLES
  • SLS
  • Nonyl Phenol Ethoxylates
Other Products+
  • Hydrochloric Acid
  • Sodium Hypochlorite
  • Phosphoric Acid
  • Mono Ethylene Glycol

Boiler Chemicals-42

Mark Ship Chandler:

LIQUIVAP TREAT

Product Code: RXSOL-60-6001-210


Product Short Description: Evaporator Treatment Chemicals
Remarks:

RXSOL-51-6001-025 is a concentrated  solution of a POLYELECTROLYTE  polymer and Antifoaming Agents for  use in SEA WATER evaporator  as a controller of scale and foam in side the  evaporators.  It can be used as a scale inhibitor  in the  feed water  to EVAPORATORS producing fresh water .

A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators

Images: Alt

Keyword

RXSOL  Evaporator Treatment is a liquid combination of active polymer and antifoam used to prevent scale deposition in high and low-pressure Evaporators. A liquid mixture of active polymer and antifoam. 

Packaging Size

Supply Location

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

AMERZAMINE

Product Code: RXSOL-14-5005-554


Product Short Description: 100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.
Remarks:

Corrosion Inhibitor for Boiler Neutralizer alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  
Corrosion Inhibitor for Boiler Neutralizer  near a heating equipment.

Images: Alt

Keyword

Why Condesate control ( Condensnol Amine ) required as BOILER Water Treatment chemicals?

Condensate control plays very important role to neutralize Acidic nature of boiler water steam during condensation process. As acidic nature rapidly corroding metal body of BOILER and surrounding system.


What is the main base and chemical principle of Condensate Control (Condensnol Amine )?

Condensate control contain mixture of condensnol amine which helps to neutralize acidic media which causes corrosion in boiler system. On the other hand we can say that condensate control works as a corrosion controler in steam and condensate systems.

Is Condensate System can be kept safe by using Condensnol amine - condensate Control?
 

Condesnol Amine ihighly effective product to CONTROL acidic strength of CONDENSATE SYSTEM. During liquid treatment Condensnol amine neutralises the acids in the condensate system.

Is Condensate control is easy to use?

Corrosion Inhibitor for Boiler Neutralizer condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of Corrosion Inhibitor for Boiler Neutralizer is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.

Packaging Size

Supply Location

Boiler Water Corrosion Inhibitor manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of chemical product at a competitive price from us. We have ready stock of chemical product in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

Multi Functional Boiler Treatment

Product Code: RXSOL-42-5001-025


Product Short Description: Highly effective multi-functional liquid reagent for the treatment of steam production systems and heating systems operating on softened water.
Remarks:

RXSOL-42-5001-025 Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting Multi Functional Boiler Treatment including scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 


Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Images: Alt

Keyword

Chemical feed should be continuous. Chemical pumping rates can create problems especially for neat feed set ups. Using on/off feed systems such as a recycle timer can create problems. Chemical feed pumps should be sized or product strengths should be adjusted to allow continuous feed.

Steam and carbon dioxide leave continuously, so setting up a neutralizing amine pump to feed intermittently can lead to wide variations in condensate pH control. If sampling is done from a condensate receiver, the tank volume may buffer the variations and the changes may not be noticed, but corrosion could be occurring to areas of the piping that see the rapidly changing pH.


If polymeric dispersants, phosphonates, phosphate, or chelants are fed intermittently into the feedwater using a recycle timer, and the amines are not fed continuously, a cycle of iron slugs returning in the condensate can be followed by slugs of high dispersancy cleaning of the iron from the deaerator and dragging it into the boiler.

Load changes can affect chemical concentrations when the chemical feed is base fed. Example: Steam production of one million lbs./day; 4% blowdown; 20% active boiler polymer product fed at 5 pounds per day. The calculated daily average polymer concentration would be 24 ppm. Assume peak plant production load is 60,000 lbs./hr., but during the overnight hours the load is only 5,000 lbs./hr. If the dispersant is being fed continuously over the 24 hours, during the 8- hour low load period, the boiler polymer concentration would have increased to over 200 ppm. Upon high fire when production resumes, carryover is very possible because of over concentrating the polymeric dispersant.

Chemical feed needs to be paced to steam production, especially where significant load changes occur.

Carbon dioxide can concentrate in steam and condensate making neutralizing amine treatment impractical. Carbon dioxide levels can be relatively low in steam exiting a boiler at only a few ppm, but if there are areas where it becomes “trapped” and can accumulate, concentrations can reach extremely high levels into the hundreds or even thousands of ppm.

CO2 is a non-condensable gas. It has a distribution ratio in the steam piping and condenses at points throughout the system. At the boiling point, the solubility of the gas in water is extremely low. The solubility of the CO2 is actually lower in the condensate than it is in the steam. For the CO2 to escape from the steam into the water it will accumulate in the steam space just above the water level until the partial pressure becomes high enough for the CO2 in the incoming steam to be able to exit into the condensate. This creates a steady state condition of CO2 coming in and exiting, but an area of severe localized corrosion occurs where the carbon dioxide concentration is high.

The highest CO2 concentration normally occurs just above the condensate water level. If there is an area where condensation is occurring and running down pipes or the sides of vessels, the CO2 concentration will be very high and the pH will be about 5.3 – 5.5 in that location creating high corrosion rates.


The solubility of CO2 increases dramatically as the condensate temperature falls below 212 °F. When there is an accumulation of CO2 in an area and the condensate temperature is relatively low, the amount of carbon dioxide going into solution will be extremely high. Where low-pressure steam is used that contains CO2 and the heat exchange process has relatively close temperature differentials between the steam and the condensate, there is potential for high uptake of the CO2 into the condensate and localized low pH.

Neutralizing amines are selected in an effort to condense in the right concentrations to carbon dioxide condensation levels throughout the steam system. Neutralizing amines cannot control corrosion where this localized accumulation of carbon dioxide occurs since the high CO2 overwhelms the demand for the amine. Even point source addition of amine may not be able to satisfy the demand.

Where the concentrating effect of CO2 occurs, methods of reducing the problem include eliminating or minimizing CO2 in the steam, venting off the CO2 in the localized area, eliminating condensate in the area, applying a filming amine or metal passivator, or using higher temperature steam and increasing condensate temperature to reduce the CO2 content in the condensate.

Packaging Size

Supply Location

Boiler water treatment speacialized chemical products One Shot Universal Liquitreat  Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

ANTISCALANT 9209 Seawater Distillation

Product Code: RXSOL-42-6005-250


Product Short Description: Antiscalant for Water Distillation Units , specially designed to control the development of scale in seawater distillation plants.
Remarks:

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
Antiscalant 9209 RX  is compatible with carbon steel and other commonly used materials of construction. Observe all safety precautions shown in the material safety data sheet, available on request.

Images: Alt

Keyword

ANTISCALANT 9209 RX seawater distillation plants, Compatible with all types of polyamide membrane
ANTISCALANT 9209 RX powerfully Inhibits common scales Calcium carbonate/sulphate - Calcium phosphateBarium/Strontium sulphate - SilicaIron/Manganese

Packaging Size

Supply Location

ANTISCALANT 9209 RX FOR seawater distillation plants manufacturer and supplier in Fujairah, Muscat, Barka, Oman, Dubai, Sharjah, Abudhabi, UAE Middle East, Ajman, Mumbai, Kolkata, Kandla, Visakhapatnam, Chennai Surat, CANADA, Kenya Nairobi, Jinja Uganda

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

Sodium Chlorite Solution 7.5 Percent

Product Code: RXSOL-42-1977-026


Product Short Description: SodiumChlorite is also used for water treatment purpose.
Remarks:
Images: Alt

Keyword

Sodium Chlorite for DRINKING WATER : When put in an acid solution, sodium chlorite breaks down into chlorine dioxide. When added to a municipal water supply, chlorine dioxide helps control unwanted tastes and odors. It also aids in the removal of ions like iron and manganese. One added benefit is that it helps eliminate trihalomethanes in drinking water.

Packaging Size

Supply Location

Sodium Chlorite Technical Grade 25% manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Sodium Chlorite Technical Grade 25% at a competitive price from us. We have ready stock of Sodium Chlorite Technical Grade 25% in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

Corrosion Scale Inhibitor Boiler Treatment

Product Code: RXSOL-42-4029-025


Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt

Keyword

Corrosion and Scale Inhibitor (Bi-functional) Cooling water System, Phosphate based product.

Packaging Size

Supply Location

Corrosion Scale Inhibitor Boiler Treatment manufacturer and supplier in Mumbai, Turbhe Pawana MIDC, Gandhidham, Visakhapatnam, Chennai Ennore, Kolkata, Haldia, Ajman, Fujairah, Dubai, Sharjah, Dubai, Muscat, Oman, Sohar, Barka, Canada, SUDAN, Yemen

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

Descalex Polymer Heat Exchanger

Product Code: RXSOL-11-1048-050


Product Short Description: Descaler has the ability to dissolve approximately 1.5kg of calcium carbonate scale per gallon in concentrated form
Remarks:

RXSOL-40-1048-025 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module Rx cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See Rx cleansers Practical Application Manual.

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Images: Alt

Keyword

Cleans complex equipment without disassembling – heat exchangers, condensers, cooling jackets, process vessels, pipings, valves & other equipments subject to rust & hard water scale deposits.

Ultra strong complexed liquid acid scale remover formulated for the fast, effective removal of hardness scale, rust & mineral deposits.

 
BULK HEAVY DUTY – RUST & SCALE REMOVING WATER DILUTABLE CONCENTRATES

Packaging Size

Supply Location

Descaling chemicals, scale remover, Descalex powder, Safe Acid manufacturer, exporter and supplier in India, Oman, Middle East. We are also popular name as a descaling chemicals supplier in Fujairah, Muscat, Mumbai, Gandhidham, Visakhapatnam, Chennai, Kolkata Howrah. And we have daily day by day descaling supply services in Dubai, Sharjah, Ajman, Abudhabi, umm al quwain in UAE, and Barka, Salalah, Sohar, Muscat in Oman, And Surat Hazira, Howrah, Paradip, Haldia, Ennore, Chennai, Visakhapatnam, Gangavaram, Jamnagar Sikka, Mundra, Kandla Gujrat, Sudan, Yemen, Africa, Nairobi KENYA

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

Zinc Chloride Solution

Product Code: RXSOL-42-6141-051


Product Short Description: Zinc chloride solution is a colorless liquid. It is mildly corrosive to metals. It causes burns to eyes skin and mucous membranes.
Remarks:
Images: Alt

Keyword

Packaging Size

Supply Location

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

Alkaline Corrosion Inhibitor for Boiler

Product Code: RXSOL-42-1308-025


Product Short Description: Caustic based alkaline corrosion inhibitor for Boiler treatment
Remarks:
Images: Alt

Keyword

Packaging Size

Supply Location

Alkaline Corrosion Inhibitor for Boiler manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Alkaline Corrosion Inhibitor for Boiler at a competitive price from us. We have ready stock of Alkaline Corrosion Inhibitor for Boiler in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.

OxyShield Plus Boiler Oxygen Scavenger

Product Code: RXSOL-42-5029-200


Product Short Description: Scavenges oxygen and passivates iron and copper surfaces, rendering them more resistant to corrosion
Remarks:

#OxygenScavengerforBoiler

#OxygenScavengermanufacturer

#OxygenScavengersupplier

#AminebasedOxygenScavenger

Images: Alt

Keyword

Packaging Size

Supply Location

Oxygen Scavenger for Boiler Water exporter and supplier in India UAE Middle East Oman Kenya Africa. Oxygen Scavenger for Boiler Water supplier in Mumbai, Kandla Surat Gujrat, Kolkata, West Bengal, Chennai Tamilnadu, Visakhapatnam, Andhra Pradesh, Dubai, Fujairah, Abudhabi, Sharjah, Ajman, Muscat Barka Sohar, Nairobi Kenya Sudan, Yemen Tanzania Africa

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.