Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.
View All Water Treatment Chemicals
One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc
View All Marine Chemicals
Ready stock of fast-running chemical raw materials in 6 key locations of India
View All ChemicalsProduct Code: RXSOL-23-1305-026
Oxygen Control
Chemical Oxygen Scavengers. The oxygen scavengers most commonly used in boiler systems are sodium sulfite, sodium bisulfite, hydrazine, catalyzed versions of the sulfites and hydrazine, and organic oxygen scavengers, such as hydroquinone and ascorbate.
It is of critical importance to select and properly use the best chemical oxygen scavenger for a given system. Major factors that determine the best oxygen scavenger for a particular application include reaction speed, residence time in the system, operating temperature and pressure, and feedwater pH. Interferences with the scavenger/oxygen reaction, decomposition products, and reactions with metals in the system are also important factors. Other contributing factors include the use of feedwater for attemperation, the presence of economizers in the system, and the end use of the steam. Chemical oxygen scavengers should be fed to allow ample time for the scavenger/oxygen reaction to occur. The deaerator storage system and the feedwater storage tank are commonly used feed points.
In boilers operating below 1,000 psig, sodium sulfite and a concentrated liquid solution of catalyzed sodium bisulfite are the most commonly used materials for chemical deaeration due to low cost and ease of handling and testing. The oxygen scavenging property of sodium sulfite is illustrated by the following reaction:
| 2Na2SO3 | + | O2 | ® | 2Na2SO4 |
| sodium Sulfite | oxygen | sodium sulfate |
Theoretically, 7.88 ppm of chemically pure sodium sulfite is required to remove 1.0 ppm of dissolved oxygen. However, due to the use of technical grades of sodium sulfite, combined with handling and blowdown losses during normal plant operation, approximately 10 lb of sodium sulfite per pound of oxygen is usually required. The concentration of excess sulfite maintained in the feedwater or boiler water also affects the sulfite requirement.
Sodium sulfite must be fed continuously for maximum oxygen removal. Usually, the most suitable point of application is the drop leg between the deaerator and the storage compartment. Where hot process softeners are followed by hot zeolite units, an additional feed is recommended at the filter effluent of the hot process units (prior to the zeolite softeners) to protect the ion exchange resin and softener shells.
As with any oxygen scavenging reaction, many factors affect the speed of the sulfite-oxygen reaction. These factors include temperature, pH, initial concentration of oxygen scavenger, initial concentration of dissolved oxygen, and catalytic or inhibiting effects. The most important factor is temperature. As temperature increases, reaction time decreases; in general, every 18°F increase in temperature doubles reaction speed. At temperatures of 212°F and above, the reaction is rapid. Overfeed of sodium sulfite also increases reaction rate. The reaction proceeds most rapidly at pH values in the range of 8.5-10.0.
The following operational conditions necessitate the use of catalyzed sodium sulfite:
High feedwater sulfite residuals and pH values above 8.5 should be maintained in the feedwater to help protect the economizer from oxygen attack.
Some natural waters contain materials that can inhibit the oxygen/sulfite reaction. For example, trace organic materials in a surface supply used for makeup water can reduce speed of scavenger/oxygen reaction time. The same problem can occur where contaminated condensate is used as a portion of the boiler feedwater. The organic materials complex metals (natural or formulated catalysts) and prevent them from increasing the rate of reaction.
Sodium sulfite must be fed where it will not contaminate feedwater to be used for attemporation or desuperheating. This prevents the addition of solids to the steam.
At operating pressures of 1,000 psig and higher, hydrazine or organic oxygen scavengers are normally used in place of sulfite. In these applications, the increased dissolved solids contributed by sodium sulfate (the product of the sodium sulfite-oxygen reaction) can become a significant problem. Also, sulfite decomposes in high-pressure boilers to form sulfur dioxide (SO2) and hydrogen sulfide (H2S). Both of these gases can cause corrosion in the return condensate system and have been reported to contribute to stress corrosion cracking in turbines. Hydrazine has been used for years as an oxygen scavenger in high-pressure systems and other systems in which sulfite materials cannot be used. Hydrazine is a reducing agent that removes dissolved oxygen by the following reaction:
| N2H4 | + | O2 | ® | 2H2O | + | N2 |
| hydrazine | oxygen | water | nitrogen |
Because the products of this reaction are water and nitrogen, the reaction adds no solids to the boiler water. The decomposition products of hydrazine are ammonia and nitrogen. Decomposition begins at approximately 400°F and is rapid at 600°F. The alkaline ammonia does not attack steel. However, if enough ammonia and oxygen are present together, copper alloy corrosion increases. Close control of the hydrazine feed rate can limit the concentration of ammonia in the steam and minimize the danger of attack on copper-bearing alloys. The ammonia also neutralizes carbon dioxide and reduces the return line corrosion caused by carbon dioxide.
Hydrazine is a toxic material and must be handled with extreme care. Because the material is a suspected carcinogen, federally published guidelines must be followed for handling and reporting. Because pure hydrazine has a low flash point, a 35% solution with a flash point of greater than 200°F is usually used. Theoretically, 1.0 ppm of hydrazine is required to react with 1.0 ppm of dissolved oxygen. However, in practice 1.5-2.0 parts of hydrazine are required per part of oxygen.
The factors that influence the reaction time of sodium sulfite also apply to other oxygen scavengers. Rate of reaction as a function of temperature and hydrazine concentration. The reaction is also dependent upon pH (the optimum pH range is 9.0-10.0)

Neutralizer for Ballast Water Management System Enviro Guard Sulfite manufacturer and supplier in Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Haldia, Paradip, Gandhidham, Hazira Surat, Muscat Oman, Barka, Ruwi, Ghala, Fujairah, Ajman, Abudhabi, Dubai, Sharjah, UAE, Nairobi Kenya, Sudan, Yemen, Canada
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-25-1011-005

Metal Clean Britte manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Metal Clean Britte at a competitive price from us. We have ready stock of Metal Clean Britte in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-25-2204-210
Refer this link for complete set of HOLD CLEANING KIT ::: http://rxmarine.com/Ship-hold-cleaning-kit-set-supplier

Ship Hold Wash cleaner Cleaning Detergent supplier in Kandla, Sikka, Navlakhi, Hazira, Jamnagar, Mumbai, JNPT, Manglore, Goa, Chennai, Ennore, Visakhapatnam, Gangavaram, Kolkata, Haldia, Buz Buz, Paradip, Fujairah. Dubai, Sharjah, Abu Dhabi, Ajman, Sohar, Muscat, Barka Ruwin Oman, Mombasa
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-25-1005-005
PROEDURE OF USE:-
1st Method:-
Mix 1 part of RXSOL-10-1005-025 with 2 -10 parts of water / GAS-OIL , For heavy oil,greasy surface use directly)Spray directly on the entire surface to be cleaned. This can be achieved by Hand spray / mechanical spray pump. Immediately after 2 -5 minute of spray the RXSOL-10-1005-025 starts its function. The Dirt, oil grease etc will loosen. 5 to 6 minutes after spraying start rinsing the system with water (High pressure recommended). Dirt and mud starts vanishing with cleaning media and water.
2nd Method:-
Application in immersion process with or without ultrasonic support, manual wipping.
3rd Method:-
RXSOL-10-1005-025 is also used in conjunction with alkaline degreasing bath at 3-5% (v/v) concentration for better and quick degreasing action. Eithers the bath is heated to be 70c or the solution can be stirred or air agitated.

Powerful Emulsifiable Solvent Degreaser with dispersing agents. Readily soluble in water in all proportions. It is non-corrosive to metal like copper, aluminium, mild steel and plastic. It is non-toxic which makes handling easy.
|
HIGH PENTERATION POWER |
KEY FEATURES
|
|
A powerful solvent-emulsifier-based degreaser formulated for tough industrial, marine, and engine cleaning tasks. It penetrates deep into grease, oil, carbon deposits, and industrial grime, breaking them down quickly for easy removal. Suitable for degreasing machinery, engine parts, bilges, tanks, and floors. Safe on most metals and painted surfaces when used as directed. |
|
We are supplier and stockist of degreaser at all major Indian ports and Middle East ports. We are popular among Ship Suppliers and Chandlers and shipping agent as a marine chemicals supplier which includes Refrigerant Freon 22, Laundry Soap and Detergents, Cleaner and Polish Goods, Hold cleaning and tank cleaning detergent, Oil spill dispersant, carbon remover, Electrocleaner, Water less hand cleaner, Teepol, Coolant, Glycol, Boiler and cooling water treatment chemicals etc...
Degreaser Heavy Duty manufacturer and supplier in Mumbai,Ruwi, Ghala, Barka, Muscat, Oman, Salalah, Fujairah, Dubai, Sharjah, Abudhabi, Ajman, Kolkata, Haldia, Paradip, Visakhapatnam, Chennai, Ennore, Navi Mumbai MIDC
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-25-3044-025
Keep away from children. Refer MSDS before using this product.

Algaecide Clarifier manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Algaecide Clarifier at a competitive price from us. We have ready stock of Algaecide Clarifier in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-25-2202-002
Cement Remover cum cleaner plays an important role to clean cement without scrubbing, which is resulting and damaging the smooth surface. Its simple application method also helps to save manpower. Youtube cement remover video available with this link https://www.youtube.com/watch?v=GJzrh60-q5w

Highly concentrated and powerful penetrating agents materials which is effectively react with cement to loosen the bonding strength . Best results can obtain on dry surface of cement. RXSOL'S R & D has developed this molecular cement dissolver as an alt
Cement remover cleaner manufacturer, supplier, exporter Mumbai, JNPT, Kandla, Sikka, Navlakhi, Manglore, Visakhapatnam, Gangavaram, Chennai, Ennore, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Abudhabi, Dubai, Barka Muscat OMAN.
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-30-1077-006
RXSOL-16-1077-020 must be used in open or sufficiently ventilated areas. RXSOL-16-1077-020 should always be used concentrate (without mixing with other solvent.) For best results apply with either by brush, swab, or as a fine spray using suitable hand held spray equipment. Small components may be cleaned by brief immersion in a bath of RXSOL-16-1077-020. Never use RXSOL-16-1077-020 on a running generator or motor. RXSOL-16-1077-020 can be used to clean virtually all electrical equipment & components although is it possible it may affect some types of rubber & plastic . Either remove rubber & plastic parts from component or test on small area for any reaction before cleaning.

| Appearance | Clear Colourless Liquid | Vapor Density : Heavier than air |
|
Flash Point |
63°C (Closed Cup) |
Stability:Very stable understandard, normal conditions |
| Compatibility | ||
| Meta Plastic Rubber |
No known effect No Known effect May swell |
Note : After use the product must always be well sealed in the drum. |
| Packaging | Order No | Size (in kgs./lts.) |
| RXSOL-16-1077-020 | 7/25 Lts |
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-81-1587-211

ORA-100, Heat Transfer Fluid manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of ORA-100, Heat Transfer Fluid at a competitive price from us. We have ready stock of ORA-100, Heat Transfer Fluid in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-25-1005-025

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.
Product Code: RXSOL-60-6302-025

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.