Water Treatment

Boiler / Cooling Tower Chemicals

Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.

View All Water Treatment Chemicals
Corrosion / Scale Control for Boiler +
  • Corrosion Scale Treatment Boiler - RXSOL-42-4029-025
  • One Shot Universal LiquiTreat - RXSOL-50-5001-020
  • MULTIPLUS BWT - RXSOL-50-5011-020
  • Sludge Conditioner - RXSOL-50-5008-020
  • Oxygen Scavenger Plus - RXSOL-50-5022-025
  • Condensol Corrosion Control - RXSOL-50-5005-025
Cooling Tower / Chiller Unit Maintenance +
  • RXSOL 2000 Corrosion Scale Inhibitor - RXSOL-40-2000-025
  • Corrosion Inhibitor MULTI Metal Protection - RXSOL-40-4011-025
  • Biocide MICRO Cooling Water - RXSOL-40-4009-025
  • Corrosion Inhibitor Antifoulant - RXSOL-40-4027-025
  • Antiscalant Antifoulant - RXSOL-33-3302-025
  • Cooling Water Test Kit - RXSOL-62-5508-001
Marine Chemicals

Marine Deck Engine Chemicals

One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc

View All Marine Chemicals
Deck Engine Maintenance +
  • Heavy Duty Degreaser - RXSOL-10-1005-025
  • TPOL Heavy Duty - RXSOL-20-T300-025
  • All Purpose Cleaner - RXSOL-12-1501-020
  • Fuel Emulsion Breaker - RXSOL-70-7003-020
  • Evaporator Treatment - RXSOL-51-6001-020
  • Electrosol Electrical Cleaner - RXSOL-16-1009-025
  • Carbon Remover - RXSOL-16-1003-025
  • Rust Stain Remover RSR - RXSOL-13-1096-025
  • Enviro Degreaser Cleaner - RXSOL-20-3001-025
  • Hand Cleaner Paste - RXSOL-16-1001-001
Ship Hold Tank Cleaning+
  • Slip Barrier Coat HOLD - RXSOL-22-2210-210
  • RXTuff High Foam - RXSOL-22-3019-210
  • Metal Clean Bright HD - RXSOL-20-1011-020
  • Coal Remover RX Hold - RXSOL-22-2215-210
  • RXSOL PCS Pet Coke Cleaner Hold - RXSOL-22-2208-025
  • Acqua Tuff High Foam - RXSOL-22-3033-210
  • Alkaline Safety Liquid - RXSOL-20-2005-026
Raw Materials

Raw Material Chemicals

Ready stock of fast-running chemical raw materials in 6 key locations of India

View All Chemicals
Inorganic / Organic Powders+
  • Caustic Soda
  • Caustic Potash
  • Sodium Nitrite
  • Sodium Bisulphite
  • Sodium Bicarbonate
Detergent Manufacturing Products+
  • Acid Slurry
  • SLES
  • SLS
  • Nonyl Phenol Ethoxylates
Other Products+
  • Hydrochloric Acid
  • Sodium Hypochlorite
  • Phosphoric Acid
  • Mono Ethylene Glycol

Membrane Cleaner Alkaline

Product Code: RXSOL-33-3323-030


Categories: RO Chemicals-33
Product Short Description: High pH liquid to remove microbiological fouling organics, silt, and other particulate deposits from polysulfone, fluorocarbon, and all polyamide thin film composite reverse osmosis (RO) and ultrafiltration (UF) membranes. The product is effectively used in nanofiltration (NF), and microfiltration (
Product Description:
ORG MC 511 (Membrane Cleaner) is a high pH liquid formulation designed to remove organics, silt, and other particulate deposits from polysulfone, fluorocarbon, and all polyamide thin film composite reverse osmosis (RO) and ultrafiltration (UF) membranes. The product is effectively used in nanofiltration (NF), and microfiltration (MF) application. This product provides superior cleanings allowing longer run times.
Product Application:

During the operation of a membrane separation system, organic materials, as well as suspended solids in the incoming water, can accumulate on the membrane surface. The presence of organic materials also provides an environment conducive to microbiological activity, which can result in microbiological fouling. Fouling from these species impedes the flow of water through the membrane. This can result in unacceptably low production, high operating pressure, or an excessive pressure drop in the system, which may lead to irreversible membrane damage. Additionally, accumulation of these foulants on the membrane surface can increase the amount of dissolved material passing through the membrane, resulting in product water of unacceptable quality. Before these foulants can accumulate to a level where product water declines or membrane damage can occur, they should be removed by a clean-in-place (CIP) off-line cleaning. Indications of the need for cleaning include a significant decrease in normalized permeate flow, a significant increase in pressure drop across the system (or individual stage), or an increase in the normalized salt passage, such that product quality is unacceptable.

Product Dose:

Dilution - The product must be diluted prior to introduction into the membrane system. The recommended dilution for this product is 500 Grams of ORG MC 511 (Membrane Cleaner) per 20 Ltrs of water.

General Cleaning Instructions

The following general cleaning procedure can be followed. For the optimum cleaning procedure for your system, contact

 Rx Marine International Representative.

  1. Inspect cleaning tank, hoses, and cartridge filter. Clean tank and flush hoses if necessary. Install new cartridge filters.
  2. Fill cleaning tank with RO permeate or DI water. Turn on agitator or tank recirculation pump.
  3. Slowly add ORG MC 511 (Membrane Cleaner)  to cleaning tank 5 Ltrs of product for every 200 Ltrs of water and allow to mix thoroughly.
  4. Check solution temperature. If solution temperature is lower than recommended level, adjust heating control to provide optimum temperature. 
  5. Check solution pH. The solution pH should be 10 to 11.5 or as recommended by the membrane manufacturer. If pH is too low, adjust pH upward with NaOH, or other chemical as recommended by the membrane manufacturer. If pH is too high, adjust with hydrochloric acid.
  6. Circulate solution through one stage at a time in the direction of feed flow for 30 minutes. Circulate at the flow rate recommended by the membrane or system manufacturer. If the manufacturer’s recommendation is not available, contact Rx Marine International representative. Pressure should be low enough so that no permeate is produced during cleaning, but always less than 60 psig (4.2 kg/cm2). In cases of heavy fouling, the first return flow (up to 15% of the cleaning tank volume) should be diverted to drain to prevent redeposition of removed solids. For optimum results, each stage must be cleaned separately in a multistage system.
  7. If the first stage cleaning solution becomes turbid or discolored, dump the tank and prepare a fresh cleaning solution before proceeding. If solution pH or temperature move out of the recommended range, a new solution should be prepared. In any event, a new cleaning solution should be prepared for each stage.
  8. Rinse with RO permeate before returning system to service.
  9. When returning unit to service, divert product water to drain until any residual cleaning solution has been rinsed from system.
Product Note:

Features of RO Membrane Cleaner Alkaline ORG MC 511 for best RO Membrane Cleaner

  • Compatible with polyamide thin-film composite membranes
  • Optimum results are obtained when used in conjunction with ORG MC 882
  • Extremely effective against oils and many other organic compounds
  • Excellent results when used to clean biological matter and eliminate biological slime from the membrane surface
  • Buffered to maintain an effective pH over a range of dilutions
  • Enhanced performance at elevated temperatures
  • Liquid cleaner which allows shorter mixing time.
  • Low foam formulation
  • No adverse effects with repeated use
  • Suitable for Reverse Osmosis (RO) and NanoFiltration (NF) membranes
  • Effective against both organic and inorganic deposits
  • Effective against iron fouling
  • Compatible with all polyamide membranes
  • Can be used in combination with other RXSOL cleaners
  • Classified as ‘readily biodegradable’
Remarks:

Materials Compatibility:
Corrosion-resistant equipment, such as PVC, should be used for the storage and preparation of this product. Pumping materials coming in contact with the concentrated or diluted products should also be corrosion resistant.

Packaging Information:
ORG MC 511 (Membrane Cleaner)  is a liquid material, available in a wide variety of customized containers and delivery methods. Contact your GE representative for details.

Safety Precautions:
A Material Safety Data Sheet containing detailed information about this product is available upon request.

Product Tag Identification:

#MembraneCleaner
#ROmembraneCLEANINGchemical
#MembraneCLEANER_MuscatOMAN
#membraneCLEANINGchemical_Dubai
#ROcleaningCHEMICALmanufacturer
#AlkalineMembraneCLeanerRO

Product Useful Area:

Cleaning procedure of RO Membranes using ORG MC 511 Membrane Cleaner Alkaline

  1. Inspect cleaning tank, hoses, and cartridge filter. Clean tank and flush hoses if necessary. Install new cartridge filters.
  2. Fill cleaning tank with RO permeate or DI water. Turn on agitator or tank recirculation pump.
  3. Slowly add ORG MC 511 (Membrane Cleaner)  to cleaning tank 5 Ltrs of product for every 200 Ltrs of water and allow to mix thoroughly.
  4. Check solution temperature. If solution temperature is lower than recommended level, adjust heating control to provide optimum temperature. 
  5. Check solution pH. The solution pH should be 10 to 11.5 or as recommended by the membrane manufacturer. If pH is too low, adjust pH upward with NaOH, or other chemical as recommended by the membrane manufacturer. If pH is too high, adjust with hydrochloric acid.
  6. Circulate solution through one stage at a time in the direction of feed flow for 30 minutes. Circulate at the flow rate recommended by the membrane or system manufacturer. If the manufacturer’s recommendation is not available, contact Rx Marine International representative. Pressure should be low enough so that no permeate is produced during cleaning, but always less than 60 psig (4.2 kg/cm2). In cases of heavy fouling, the first return flow (up to 15% of the cleaning tank volume) should be diverted to drain to prevent redeposition of removed solids. For optimum results, each stage must be cleaned separately in a multistage system.
  7. If the first stage cleaning solution becomes turbid or discolored, dump the tank and prepare a fresh cleaning solution before proceeding. If solution pH or temperature move out of the recommended range, a new solution should be prepared. In any event, a new cleaning solution should be prepared for each stage.
  8. Rinse with RO permeate before returning system to service.
  9. When returning unit to service, divert product water to drain until any residual cleaning solution has been rinsed from system.

Keyword

RO Membrane Cleaner Alkaline manufacturer supplier in UAE, RO Membrane Cleaner Alkaline manufacturer distributor in Oman, RO Membrane Cleaner Alkaline manufacturer exporter in India 

Packaging Size

Supply Location

Membrane Cleaner Alkaline manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Membrane Cleaner Alkaline at a competitive price from us. We have ready stock of Membrane Cleaner Alkaline in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.