Product Category

Water Treatment

Boiler / Cooling Tower Chemicals

Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.

View All Water Treatment Chemicals
Corrosion / Scale Control for Boiler +
  • Corrosion Scale Treatment Boiler - RXSOL-42-4029-025
  • One Shot Universal LiquiTreat - RXSOL-50-5001-020
  • MULTIPLUS BWT - RXSOL-50-5011-020
  • Sludge Conditioner - RXSOL-50-5008-020
  • Oxygen Scavenger Plus - RXSOL-50-5022-025
  • Condensol Corrosion Control - RXSOL-50-5005-025
Cooling Tower / Chiller Unit Maintenance +
  • RXSOL 2000 Corrosion Scale Inhibitor - RXSOL-40-2000-025
  • Corrosion Inhibitor MULTI Metal Protection - RXSOL-40-4011-025
  • Biocide MICRO Cooling Water - RXSOL-40-4009-025
  • Corrosion Inhibitor Antifoulant - RXSOL-40-4027-025
  • Antiscalant Antifoulant - RXSOL-33-3302-025
  • Cooling Water Test Kit - RXSOL-62-5508-001
Marine Chemicals

Marine Deck Engine Chemicals

One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc

View All Marine Chemicals
Deck Engine Maintenance +
  • Heavy Duty Degreaser - RXSOL-10-1005-025
  • TPOL Heavy Duty - RXSOL-20-T300-025
  • All Purpose Cleaner - RXSOL-12-1501-020
  • Fuel Emulsion Breaker - RXSOL-70-7003-020
  • Evaporator Treatment - RXSOL-51-6001-020
  • Electrosol Electrical Cleaner - RXSOL-16-1009-025
  • Carbon Remover - RXSOL-16-1003-025
  • Rust Stain Remover RSR - RXSOL-13-1096-025
  • Enviro Degreaser Cleaner - RXSOL-20-3001-025
  • Hand Cleaner Paste - RXSOL-16-1001-001
Ship Hold Tank Cleaning+
  • Slip Barrier Coat HOLD - RXSOL-22-2210-210
  • RXTuff High Foam - RXSOL-22-3019-210
  • Metal Clean Bright HD - RXSOL-20-1011-020
  • Coal Remover RX Hold - RXSOL-22-2215-210
  • RXSOL PCS Pet Coke Cleaner Hold - RXSOL-22-2208-025
  • Acqua Tuff High Foam - RXSOL-22-3033-210
  • Alkaline Safety Liquid - RXSOL-20-2005-026
Raw Materials

Raw Material Chemicals

Ready stock of fast-running chemical raw materials in 6 key locations of India

View All Chemicals
Inorganic / Organic Powders+
  • Caustic Soda
  • Caustic Potash
  • Sodium Nitrite
  • Sodium Bisulphite
  • Sodium Bicarbonate
Detergent Manufacturing Products+
  • Acid Slurry
  • SLES
  • SLS
  • Nonyl Phenol Ethoxylates
Other Products+
  • Hydrochloric Acid
  • Sodium Hypochlorite
  • Phosphoric Acid
  • Mono Ethylene Glycol

Corrosion Inhibitor for Multi Metal Cooling Water

Product Code: RXSOL-40-4011-020


Product Short Description: Corrosion Inhibitor for Multi Metal Cooling Water is a specially formulated corrosion inhibitor blend designed to protect multiple metals commonly found in closed recirculating cooling and retort water systems.
Product Description:

RXSOL Corrosion Inhibitor for Multi Metal Cooling Water

 

Product Code: RXSOL-40-4011-020
Application: Treatment of Cooling and Retort Water

PRODUCT DESCRIPTION AND APPLICATION

 

RXSOL Corrosion Inhibitor for Multi Metal Cooling Water is a specially formulated corrosion inhibitor blend designed to protect multiple metals commonly found in closed recirculating cooling and retort water systems.

RXSOL-40-4011-020 is easy to apply and control. Its built-in pH buffering system helps maintain the circulating water within an optimum pH range, thereby reducing corrosion and providing effective protection to system metallurgy.

The product provides corrosion protection for systems containing carbon steel, copper, brass and other compatible metals and alloys, making it particularly suitable for multi-metal closed cooling circuits.

An indicating dye incorporated into the formulation assists with visual identification of treated water and can help in the detection of system leakage.

RXSOL-40-4011-020 is suitable for use with uninhibited antifreeze solutions and is formulated to be compatible with commonly used gaskets, pump seals and other non-metallic components when used at the recommended concentration.

Corrosion Inhibitor Additives for Water system ::: Alkaline Corrosion Inhibitor blend for multi-metal protection in closed-loop and chilled cooling water CLOSED circulating system.
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of molybdate, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and also a variant pink appearance form.
 

RXSOL-40-4011-020 is a superior multifunctional, molybdate-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

 

 


 

Product Application:

Applications

RXSOL-40-4011-020 is recommended for:

 

  • Closed recirculating cooling-water systems
  • Retort cooling-water systems
  • Engine and machinery cooling circuits
  • Chilled-water systems
  • Closed-loop industrial cooling systems
  • Multi-metal cooling circuits
  • Systems containing glycol-based uninhibited antifreeze
  • Industrial equipment requiring long-term corrosion protection

Cooling water treatment specified corrosion inhibitior for multi-metal containng cooling systems to operate at high or low temperatures.

Alkaline Corrosion Inhibitor blend for multi-metal protection in closed-loop and chilled cooling water CLOSED circulating system

Product Dose:

For systems containing no aluminium, RXSOL-40-4011-020 should be dosed at 0.5 to 1% (5 L–10 L/ 1000 L) in order to give a reserve of 50 ppm of sodium molybdate. For systems containing aluminium, the dosage of 1–1.5% should be added in order to maintain a minimum reserve of 100 ppm of sodium molybdate. In certain circumstances it may be necessary to adjust the pH separately by the addition of pH CONDITIONER - your Consultant will advise. In systems requiring significant passivation/higher initial dosages may be required to yield the required inhibitor residual.

Normal treated water control limits

pH 7.0 - 9.0 (Without Aluminium)

pH 7.0 - 8.0 (With Aluminium)

For systems containing aluminium it is important to maintain the system water pH in the range 7.0 - 8.0. Occasionally depending on the water characteristics and system treatment history the pH may rise above pH 8.0 which means that the risk of aluminium corrosion is increased - if this happens then high pH can be reduced by adding an appropriate quantity of pH Conditioner.

Product Note:

Very effective to Controls corrosion on brass, aluminum, steel, and stainless steel
Extends equipment life & Improves overall equipment efficiency

 

  • Corrosion Control: Protects internal metal surfaces like steel, brass, and aluminum in closed circulating systems.
  •  

  • Active Ingredients: Contains chemical substances including silicates and sodium molybdate.
  •  

  • System Type: Designed for industrial hot and chilled water loops requiring stable scale and corrosion control
  • Remarks:

    Keep in a tightly closed container in storage closed area . Recommended storage temperature is 500C
     

    Product Tag Identification:
    Product Useful Area:

    Keyword

    How to Maximize efficiency of Cooling Tower / Chiller Systems

    • Control Scale Formation: Maintain proper water chemistry and use an effective scale inhibitor to prevent calcium, magnesium and silica deposits on heat-transfer surfaces.
    • Prevent Corrosion: Maintain pH within the recommended operating range and use suitable corrosion inhibitors to protect carbon steel, copper and other system metals.
    • Control Microbiological Growth: Maintain an effective biocide program to control bacteria, algae, fungi and biofilm that can reduce heat transfer and restrict water flow.
    • Optimize Cycles of Concentration: Monitor conductivity/TDS and control blowdown to maximize water efficiency without allowing excessive dissolved solids or scaling.
    • Keep Heat-Transfer Surfaces Clean: Regularly inspect and clean condenser tubes, evaporators, cooling-tower fill and strainers. Even relatively thin deposits can reduce heat-transfer efficiency.
    • Monitor Chilled & Condenser Water: Routinely check pH, conductivity, hardness, alkalinity, chlorides and inhibitor residuals; investigate abnormal trends before they develop into major problems.
    • Maintain Proper Water Flow: Inspect pumps, strainers, nozzles, valves and cooling-tower distribution systems to ensure uniform flow and avoid low-flow areas, fouling and poor heat transfer.
    • Inspect & Clean Regularly: Schedule periodic cleaning, descaling and system inspection based on operating conditions and water-quality trends rather than waiting for a noticeable loss of performance.
    • Track System Performance: Log temperatures, pressures, approach temperature, conductivity, chemical residuals, make-up and blowdown. Trending these values helps identify fouling and efficiency losses early.
    • Protect During Shutdown: For seasonal or standby systems, drain or preserve equipment correctly and maintain appropriate corrosion and microbiological protection during extended shutdown periods.

    Packaging Size

    Supply Location

    Corrosion Inhibitor for Multi Metal Cooling Water manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Corrosion Inhibitor for Multi Metal Cooling Water at a competitive price from us. We have ready stock of Corrosion Inhibitor for Multi Metal Cooling Water in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

    Free Delivery / Supply Locations

    Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.