Product Category

Water Treatment

Boiler / Cooling Tower Chemicals

Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.

View All Water Treatment Chemicals
Corrosion / Scale Control for Boiler +
  • Corrosion Scale Treatment Boiler - RXSOL-42-4029-025
  • One Shot Universal LiquiTreat - RXSOL-50-5001-020
  • MULTIPLUS BWT - RXSOL-50-5011-020
  • Sludge Conditioner - RXSOL-50-5008-020
  • Oxygen Scavenger Plus - RXSOL-50-5022-025
  • Condensol Corrosion Control - RXSOL-50-5005-025
Cooling Tower / Chiller Unit Maintenance +
  • RXSOL 2000 Corrosion Scale Inhibitor - RXSOL-40-2000-025
  • Corrosion Inhibitor MULTI Metal Protection - RXSOL-40-4011-025
  • Biocide MICRO Cooling Water - RXSOL-40-4009-025
  • Corrosion Inhibitor Antifoulant - RXSOL-40-4027-025
  • Antiscalant Antifoulant - RXSOL-33-3302-025
  • Cooling Water Test Kit - RXSOL-62-5508-001
Marine Chemicals

Marine Deck Engine Chemicals

One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc

View All Marine Chemicals
Deck Engine Maintenance +
  • Heavy Duty Degreaser - RXSOL-10-1005-025
  • TPOL Heavy Duty - RXSOL-20-T300-025
  • All Purpose Cleaner - RXSOL-12-1501-020
  • Fuel Emulsion Breaker - RXSOL-70-7003-020
  • Evaporator Treatment - RXSOL-51-6001-020
  • Electrosol Electrical Cleaner - RXSOL-16-1009-025
  • Carbon Remover - RXSOL-16-1003-025
  • Rust Stain Remover RSR - RXSOL-13-1096-025
  • Enviro Degreaser Cleaner - RXSOL-20-3001-025
  • Hand Cleaner Paste - RXSOL-16-1001-001
Ship Hold Tank Cleaning+
  • Slip Barrier Coat HOLD - RXSOL-22-2210-210
  • RXTuff High Foam - RXSOL-22-3019-210
  • Metal Clean Bright HD - RXSOL-20-1011-020
  • Coal Remover RX Hold - RXSOL-22-2215-210
  • RXSOL PCS Pet Coke Cleaner Hold - RXSOL-22-2208-025
  • Acqua Tuff High Foam - RXSOL-22-3033-210
  • Alkaline Safety Liquid - RXSOL-20-2005-026
Raw Materials

Raw Material Chemicals

Ready stock of fast-running chemical raw materials in 6 key locations of India

View All Chemicals
Inorganic / Organic Powders+
  • Caustic Soda
  • Caustic Potash
  • Sodium Nitrite
  • Sodium Bisulphite
  • Sodium Bicarbonate
Detergent Manufacturing Products+
  • Acid Slurry
  • SLES
  • SLS
  • Nonyl Phenol Ethoxylates
Other Products+
  • Hydrochloric Acid
  • Sodium Hypochlorite
  • Phosphoric Acid
  • Mono Ethylene Glycol

SULPHITE (SULFITE) LAB TEST METHOD Supplier in Sohar Muscat Barka Ruwi Madayn

on 25 Nov 2022 10:01 AM
  • SULPHITE (SULFITE) LAB TEST METHOD Sohar Muscat Barka Ruwi Madayn
Product Short Description: The determination of sulfite usually is made only on boiler waters or on waters that have been treated with catalyzed sodium sulfite for corrosion prevention. Product Description: Summary of Method The water sample is acidified and titrated with a potassium iodide-iodate standard solution. The acid releases free iodine, which is reduced to colorless iodide by the sulfite in the sample. When all of the sulfite is gone, the iodine reacts with the starch indicator to form a blue color. Reagents Sulfuric acid, H2 SO4 ::: RXSOL-60-6186-500 Starch indicator ::: RXSOL-60-6221-100 Sulfite Indicator Powder: ::: RXSOL-62-5503-005 a proprietary formulation containing sulfamic acid to destroy nitrite. Standard potassium iodide-iodate titrant ::: RXSOL-62-5503-006 This titrant is equivalent to 500 mu (μ) g SO3 /1.00 mL. Sulfamic Acid: Crystalline EDTA Reagent ::: RXSOL-60-6168-500 Dissolve 2.5 g EDTA in 100 mL distilled water. Procedure Sampling Contact with air must be minimized. If the sample temperature is greater than 50°C, it must be cooled in a air tight apparatus. Immediately add 1 mL of EDTA Solution (5.6) per 100 mL of sample. 1st Method Place 1 mL H2SO4 in titration vessel. Add 0.1 g sulfamic acid crystals. Add 50 mL sample. Add approximately 0.1 g starch indicator. Titrate with potassium iodide-iodate titrant (5.4) until a faint permanent blue color develops. Keep the pipet tip below the surface of the sample. View the color change against a white background. Record the mL titrant. ---- VALUE of A Run a reagent blank using distilled water instead of sample. 2nd Method Place 50 mL sample in a titration vessel. Add 3-4 drops phenolphthalein indicator. Add sufficient scoops (1 g) of indicator ( Sulfite Indicator Powder: ::: RXSOL-62-5503-005 ) to discharge the red color. Titrate with potassium iodide-iodate titrant until a faint permanent blue color develops. View the color change against a white background. Record the mL titrant. ---- VALUE of A Run a reagent blank using distilled water instead of sample.