Water Treatment

Boiler / Cooling Tower Chemicals

Specialized formulatory products for efficient maintenance of boiler units and chiller plants of industries.

View All Water Treatment Chemicals
Corrosion / Scale Control for Boiler +
  • Corrosion Scale Treatment Boiler - RXSOL-42-4029-025
  • One Shot Universal LiquiTreat - RXSOL-50-5001-020
  • MULTIPLUS BWT - RXSOL-50-5011-020
  • Sludge Conditioner - RXSOL-50-5008-020
  • Oxygen Scavenger Plus - RXSOL-50-5022-025
  • Condensol Corrosion Control - RXSOL-50-5005-025
Cooling Tower / Chiller Unit Maintenance +
  • RXSOL 2000 Corrosion Scale Inhibitor - RXSOL-40-2000-025
  • Corrosion Inhibitor MULTI Metal Protection - RXSOL-40-4011-025
  • Biocide MICRO Cooling Water - RXSOL-40-4009-025
  • Corrosion Inhibitor Antifoulant - RXSOL-40-4027-025
  • Antiscalant Antifoulant - RXSOL-33-3302-025
  • Cooling Water Test Kit - RXSOL-62-5508-001
Marine Chemicals

Marine Deck Engine Chemicals

One STOP manufacturer for all of vessel's chemical needs - chemicals, test kits, applicators, etc

View All Marine Chemicals
Deck Engine Maintenance +
  • Heavy Duty Degreaser - RXSOL-10-1005-025
  • TPOL Heavy Duty - RXSOL-20-T300-025
  • All Purpose Cleaner - RXSOL-12-1501-020
  • Fuel Emulsion Breaker - RXSOL-70-7003-020
  • Evaporator Treatment - RXSOL-51-6001-020
  • Electrosol Electrical Cleaner - RXSOL-16-1009-025
  • Carbon Remover - RXSOL-16-1003-025
  • Rust Stain Remover RSR - RXSOL-13-1096-025
  • Enviro Degreaser Cleaner - RXSOL-20-3001-025
  • Hand Cleaner Paste - RXSOL-16-1001-001
Ship Hold Tank Cleaning+
  • Slip Barrier Coat HOLD - RXSOL-22-2210-210
  • RXTuff High Foam - RXSOL-22-3019-210
  • Metal Clean Bright HD - RXSOL-20-1011-020
  • Coal Remover RX Hold - RXSOL-22-2215-210
  • RXSOL PCS Pet Coke Cleaner Hold - RXSOL-22-2208-025
  • Acqua Tuff High Foam - RXSOL-22-3033-210
  • Alkaline Safety Liquid - RXSOL-20-2005-026
Raw Materials

Raw Material Chemicals

Ready stock of fast-running chemical raw materials in 6 key locations of India

View All Chemicals
Inorganic / Organic Powders+
  • Caustic Soda
  • Caustic Potash
  • Sodium Nitrite
  • Sodium Bisulphite
  • Sodium Bicarbonate
Detergent Manufacturing Products+
  • Acid Slurry
  • SLES
  • SLS
  • Nonyl Phenol Ethoxylates
Other Products+
  • Hydrochloric Acid
  • Sodium Hypochlorite
  • Phosphoric Acid
  • Mono Ethylene Glycol

Copper Sulfate LR for passivation test

Product Code: RXSOL-60-6116-500


Product Short Description: Detect the presence of metallic iron and iron oxide. Chromium and nickel will not be replaced with the Copper sulfate test solution, forming the distinctive copper color on the surface in this 6 minute test.
Product Description:

The copper sulfate test is used to detect the presence of metallic iron and iron oxide on the surface of materials.

Question - What solution strength is needed to copper sulfate solution can be used to determine if a metal is stainless steel or just steel ? 
Answer    - Copper sulfate (CuSO4*5H2O) + H2SO4 (anywhere from 1% to 50% is specified in various test methods).

Product Application:

How does copper sulfate test for passivation work?

ANSWER : Chromium and nickel will not be replaced with the Copper sulfate test solution (which also contains sulfuric acid), only the Fe or other less noble metals. If there is free iron on the surface it will be replaced by the copper, forming the distinctive copper color on the surface in this 6 minute test. Of course, this test should only be used on austenitic stainless steel. Some people use it on other grades, but you can get false failures.

 

 

Click here for PASSIVATING LIQUID technical information , to know Other testing methods for PASSIVATION , Passivation Method

Product Dose:

Spray the surface with a solution of copper sulfate in water. If free iron is present, a copper film will form. In this test, the chemical reaction is:

 Fe + CuSO4 = FeSO4 + Cu
The copper film is immediately visible.
 

Copper sulphate test: a galvanic type test in which the more noble copper plays upon less noble iron particles but not on SS.  Patches of copper sulphate shows a poorly passivated surface. Passivated parts are immersed in a Copper Sulfate solution for five minutes, rinsed and visually examined. Any copper (pink) color indicates the presence of free iron and the test is considered unacceptable.

Ferroxyl test: causes coloured iron compounds to appear as specks.

Product Note:
Remarks:
Product Tag Identification:
Product Useful Area:

Keyword


Packaging Size

Supply Location

Copper Sulfate LR for passivation test manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Copper Sulfate LR for passivation test at a competitive price from us. We have ready stock of Copper Sulfate LR for passivation test in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Mina Zayed, Khalifa Port, Kizad, Jebel Ali, Port Rashid, Khor Fakkan, Sharjah Creek, Port of Hamriyah, Mussafah Port, Saqr Port, Dibba Port, Jebel Dhanna, Mina Al Hamriya, and all major UAE ports.